Conventional Instrument Cluster
1. Verify the customer's concern by operating the instrument cluster to duplicate the condition. Observe the indicators and gauges to determine if they are operating properly with the ignition switch:- In RUN with the engine OFF.
- In START before the ignition switch is released.
- In RUN with the engine running.
2. Inspect to determine if any of the following mechanical or electrical concerns apply.
VISUAL INSPECTION CHART
Mechanical
- Damaged fuel tank.
- Engine coolant level.
- Accessory drive belt.
Electrical
- Fuse junction panel fuse:
- CLUSTER(5A)
- Run(5A)
- INTLPS(10A)
- Circuit wiring.
- Switches, sensors or modules.
3. If the inspection reveals obvious concern(s) that can be readily identified, service as required.
4. If the concern(s) remains after the inspection, determine the symptoms and go to the Symptom Chart. Conventional Instrument Cluster