Instrument Cluster - Printed Circuit
REMOVAL1. Remove instrument cluster.
2. Remove seven retaining screws from instrument cluster main lens and instrument cluster mask assembly and remove instrument cluster main lens and instrument cluster mask.
3. Remove gauges and speedometer assembly.
4. Depress clip on instrument cluster printed circuit and remove instrument cluster printed circuit from instrument cluster back plate.
5. Remove instrument panel lamp socket and bulbs.
6. Remove clip assemblies by squeezing on each side and pushing them through instrument cluster back plate.
7. Remove instrument cluster printed circuit from instrument cluster back plate.
INSTALLATION
1. Position instrument cluster printed circuit over locating pins on instrument cluster back plate.
2. Push clips through instrument cluster printed circuit and instrument cluster back plate.
3. Install instrument panel lamp socket and bulbs.
NOTE: An audible click will be heard when clips lock into position.
4. Install instrument cluster printed circuit assembly.
5. Install gauges and speedometer assembly.
6. Position instrument cluster mask and instrument cluster main lens assemblies on locating pins and install seven retaining screws.
7. Install instrument cluster.