D4 Check For Short to Ground In 60A ABS Fuse Circuit
- Key OFF.
- Disconnect the anti-lock relay connector.
- Remove the 60A ABS fuse.
- Measure the resistance of the "BK/BL" wire between the negative terminal of the 60A ABS fuse socket and ground.
- Is the resistance greater than 10,000 ohms?
YES -- If 10A ABS fuse blown, Go to D5. D5 Check For Short to Ground In 10A ABS Fuse Circuit
If 10A ABS fuse OK, Go to D6. D6 Check ABS Relay
NO -- Service the "BK/BL" wire. If 10A ABS fuse is blown, Go to D5. D5 Check For Short to Ground In 10A ABS Fuse Circuit