Positive Crankcase Ventilation Valve: Service and Repair
Crankcase Ventilation Hose:
REMOVAL and INSTALLATION
1. Remove Positive Crankcase Ventilation (PCV) valve from PCV valve grommet in RH valve cover.
2. Disconnect crankcase ventilation hose from PCV valve.
3. Inspect PCV valve and grommet for deterioration. Replace as necessary.
4. To install, reverse Removal procedure.