PCV Tube - Water Pump Drive Pulley Contact
Article No.96-10-5
05/06/96
^ EMISSIONS - PCV TUBE WEAR - THROUGH FROM CONTACT WITH WATER PUMP DRIVE PULLEY - 2.5L ENGINE
^ ENGINE - 2.5L - PCV TUBE WEAR - THROUGH FROM CONTACT WITH WATER PUMP DRIVE PULLEY
FORD:
1995-96 CONTOUR
LINCOLN-MERCURY:
1995-96 MYSTIQUE
This TSB article is being republished in its entirety to provide better servicing information.
ISSUE:
The LH side PCV Closure Tube may have a hole worn through it. This is due to mispositioning of the PCV closure tube in prior repairs. The tube then comes into contact with the water pump drive pulley which wears the tube.
ACTION:
Replace both the PCV closure tube and water pump pulley shield when servicing either the tube or the shield. The revised water pump pulley shield will improve the protection of the PCV closure tube, and provide a better routing of the tube. Refer to Instruction Sheet 7138, found in the Pulley Shield/Closure Tube kit, for details.
The Pulley Shield/Closure Tube kit contains the following:
^ PCV Closure Tube
^ Water Pump Pulley Shield
^ Bolt
^ Instruction Sheet (I.S. # 7138)
PART NUMBER PART NAME
F6RZ-6A647-AA Water Pump Pulley Shield/PCV Closure Tube Kit
OTHER APPLICABLE ARTICLES: NONE
SUPERSEDES: 95-19-5
WARRANTY STATUS: Eligible Under The Provisions Of Bumper To Bumper Warranty Coverage And Emissions Warranty Coverage
OPERATION DESCRIPTION TIME
961005A Replace PCV Closure 0.3 Hr.
Tube And Water Pump
Pulley Cover
DEALER CODING
CONDITION
BASIC PART NO. CODE
6758 30
OASIS CODES: 401000, 611000, 611500