PCV Valve Hose: Service and Repair
1. Remove water pump pulley shield.2. Remove crankcase ventilation tube from RH and LH valve cover.
3. Remove crankcase ventilation tubes from air cleaner outlet tube fittings.
4. Inspect crankcase ventilation tubes for deterioration. Replace as necessary.
5. To install, reverse removal procedure.