Component Transfer

1. Transfer the oxygen sensor and catalyst monitor from the old front (left) catalyst/exhaust manifold to the new catalyst/exhaust manifold.

2. Tighten oxygen sensor to 35-46 N-m (26-34 lb/ft).

3. Tighten catalyst monitor to 35-46 N-m (26-34 lb/ft).