D5 Check For Short to Ground In 10A ABS Fuse Circuit
- Key OFF.
- Disconnect the anti-lock relay connector.
- Disconnect the anti-lock brake control module connectors.
- Disconnect the interior fuse junction panel connector.
- Measure the resistance of the "BK/O" wire between the anti-lock relay connector and ground.
- Is the resistance greater than 10,000 ohms?
YES -- Service the "BK/O" wire.
NO -- Go to D6. D6 Check ABS Relay