D4 Check For Short to Ground In 60A ABS Fuse Circuit
- Key OFF.
- Disconnect the anti-lock relay connector.
- Remove the 60A ABS fuse.
- Measure the resistance of the "BK/BL" wire between the negative terminal of the 60A ABS fuse socket and ground.
- Is the resistance greater than 10,000 ohms?
YES -- Service the "BK/BL" wire. If 10A ABS fuse is blown, go to D5. D5 Check For Short to Ground In 10A ABS Fuse Circuit
NO -- (10A ABS fuse blown). Go to D5. D5 Check For Short to Ground In 10A ABS Fuse Circuit
NO -- (10A ABS fuse OK). Go to D6. D6 Check ABS Relay