DD2 Check RH Front Sensor Resistance
- Disconnect RH front sensor plug.
Sensor Plug Terminals:
- Measure resistance of front brake anti-lock sensor at sensor plug.
- Is resistance between 800 and 1400 ohms?
YES -- Service circuit 514 or 516.
NO -- Replace RH front brake anti-lock sensor.