X16 - Check VPWR Circuit to CCRM
- Key "OFF".
- Constant Control Relay Module (CCRM) disconnected.
- Disconnect EEC-IV power relay.
EEC-IV Power Relay Connector:
- Measure resistance between Pin 13 at the CCRM vehicle harness connector and the VPWR circuit at the EEC-IV power relay vehicle harness connector.
- Is resistance less than 5.0 ohms?
Yes -- Reconnect EEC-IV power relay. Go to X17. X17 - Check HFC Circuit Continuity
No -- Service open in VPWR circuit between EEC-IV power relay and CCRM. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)