FF16 DTC 64
- Turn ignition switch OFF.
Anti-Lock Module:
- Disconnect anti-lock brake wiring plug from anti-lock brake control module.
Break Out Box:
- Connect 60-pin Rotunda Breakout Box 014-00322 with Anti-Lock Brake Adapter T90P-50-ALA to the anti-lock 55-pin plug harness.
- Jumper pins 15, 34 and 60.
- Apply and hold brake pedal.
- Turn ignition switch to ON.
- Does brake pedal rise?
YES -- Reverify code 64.
NO -- Replace pump motor assembly.