FA3 - Check For Short(s) to Ground
^ Key "OFF".
^ Disconnect the fuel pump relay.
^ Disconnect the powertrain control module.
^ Disconnect the fuel pump connector at the fuel pump assembly.
^ Measure the resistances between the following wires at the fuel pump relay connector and ground.
- BK/PK
- LG
^ Are the resistances greater than 10,000 ohms?
YES -- Go to FA4. FA4 - Check Power Supply to Fuel Pump Relay
NO -- Service the wire(s) in question for a short.