E3 - Check Second Motor Power Ground
^ Measure resistance between pin 19 (circuit 57, BK) of mating connector for passive restraint module to chassis ground.
^ Is continuity present?
YES -- Grounds OK. Return to the original pinpoint test.
NO -- Service circuit 57 (BK). Install original passive restraint module.