KL5 - Check SIL Dimmer Relay Function
- Key "OFF".
- Shift Indicator Light (SIL) dimmer relay disconnected.
- Apply 12 volts across Pins 1 and 2 on the SIL dimmer relay.
- Measure resistance between Pins 3 and 5 on SIL dimmer relay.
- Is resistance between 40 ohms and 55 ohms?
Yes -- Go to KL6. KL6 - Check Voltage At SIL Dimmer Relay
No -- Replace SIL dimmer relay. Verify SIL operation.