B10 - Check Continuity GND Circuit Between PWR Relay And CCRM
- Key "OFF".
- Electronic Engine Controls (EEC) power relay disconnected.
- Disconnect Constant Control Relay Module (CCRM).
- Measure resistance between GND circuit at the EEC power relay vehicle harness connector and Pin 9 of the CCRM vehicle harness connector.
- Is resistance less than 5.0 ohms?
Yes -- Go to B11. B11 - Check Ground Circuit Continuity In CCRM
No -- Service open GND circuit between EEC power relay and CCRM. Remove breakout box. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)