DD2 Check FLS No. 2 Switch
- Disconnect 2-pin plug on Fluid Level Switch (FLS) located on brake master cylinder filler cap on hydraulic control unit reservoir.
Connector:
- Check for continuity between each pin and body ground.
- Is continuity present?
YES -- Replace brake master cylinder filler cap.
NO -- Service or replace cable harness circuit 542, 535, or 549.