X17 - Check HFC Circuit For Short to Power
- Key Off.
- Breakout box installed, PCM disconnected.
- CCRM disconnected.
- Key On.
- Measure voltage between Test Pin 17 and battery negative post.
- Is voltage less than 1.0 volt?
YES -- Key Off. GO to X18. X18 - Check HFC Circuit For Shorts to Ground
NO -- SERVICE short to power. REMOVE breakout box. RECONNECT all components. Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes