HV4 - Check CANP For Vacuum Leaks - Closed Vacuum Position
- Key On, Engine Off.
- CANP solenoid disconnected.
- Disconnect vacuum hose at CANP solenoid on the manifold vacuum side of the CANP solenoid.
- Apply 16 inHg (53 kPa) of vacuum to the manifold vacuum side of the CANP solenoid.
- Does the CANP solenoid hold vacuum for 20 seconds?
YES -- LEAVE the vacuum pump connected. Go to HV5. HV5 - Check CANP Mechanical Operation - Open Vacuum Position
NO -- REPLACE CANP solenoid. Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes