DR8 - Check For Shorts In PCM
- Key Off.
- CMP sensor disconnected.
- Breakout box installed.
- Connect PCM to breakout box.
- Measure resistance between Test Pin 85 (CID) and Test Pins 51,103 (PWR GND), 71, 97 (VPWR), 91 (SIG RTN), and 23 (IGN GND) at the breakout box.
- Is each resistance greater than 500 ohms?
YES -- Go to DR9. DR9 - Check CMP Sensor Output
NO -- REPLACE PCM. REMOVE breakout box. RECONNECT all components. Rerun quick test. Diagnostic Subroutines (DSR) - Extracting Codes