E2 Check Circuit 539
- Disconnect pump motor relay from 4-pin plug.
- Connect EEC-IV Breakout Box 014-00322 with Anti-Lock Test Adapter T90P-50-ALA to the anti-lock 55-pin plug wiring harness.
- Check for continuity between breakout box pins 15 and 60.
- Is continuity present?
YES -- Service or replace cable harness circuit 539.
NO -- Replace pump motor relay.