X26 - FC/LFC Circuit Fault Isolation Check
- Key "OFF".
- Breakout box installed, Powertrain Control Module (PCM) disconnected.
- Reconnect Constant Control Relay Module (CCRM).
- Key "ON", engine "OFF".
- Jumper test pin 13 to test pin 40 or 60 at the breakout box.
- Does fan continue to run?
Yes -- Key "OFF". Remove jumper. If Diagnostic Trouble Code (DTC) 563 was also present with the 564, go to X150. X150 - Check HFC Circuit For Short to Ground
If not, replace CCRM. Remove breakout box. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)