EV 6 - Check Rollover/Vent Valve Function
Rollover Vent Valve:
EV6 CHECK ROLLOVER/VENT VALVE FUNCTION
^ Check the rollover/vent valve for evidence of leakage.
^ Remove the rollover/vent valve.
^ Connect Rotunda Vacuum/Pressure Tester 059-00008 or equivalent, to the rollover/vent valve as shown for Test 1.
^ Hold the valve vertically.
^ Blow into port A and verify the valve opens at 7.0 kPa (1.0 psi) maximum.
^ Connect the tester as shown for Test 2.
^ Blow into port B and verify the valve opens at 4.9 kPa (0.7 psi) maximum.
^ Hold the valve upside down.
^ Blow into port A and verify that pressure is held.
^ Does the valve function properly?
YES -- Evaporative Emissions system is OK.
NO -- Replace the rollover/vent valve.