A31 - Check CKP+ For Short High - Bias High Fault
^ Key off.
^ Disconnect ICM from ICM tee. Leave EI diagnostic harness connected to vehicle harness connector.
^ DVOM on 20 volt DC scale.
^ Key on, engine off.
^ Measure voltage between (+)J35 (CKP+ I) and (-)J7 (B-) at breakout box.
^ Is DC voltage less than 0.5 volts?
YES -- Replace ICM. CKP+ is shorted high. Remove all test equipment. Reconnect all components. Clear continuous memory. Rerun quick test.
NO -- Check connectors, service or replace harness. CKP+ is shorted high. Remove all test equipment. Reconnect all components. Clear continuous memory. Rerun quick test.