Radiator Cooling Fan Control Module: Service and Repair
Constant Control Relay Module:
REMOVAL AND INSTALLATION
1. Remove radiator sight shield.
2. Disconnect electrical connection Remove
integrated relay control assembly located on radiator support.
3. Disconnect electric fan connector.
4. Unbolt fan and shroud assembly from radiator.
5. Slide cooling fan module clear of radiator hose connector and lift up past radiator.
6. Remove fan U-spring and remove fan.
7. Remove fan motor from shroud.
8. To install, reverse Steps 1 through 7. Tighten fan retaining screws to 10 Nm (86 lb-in). Tighten shroud retaining nuts and bolts to 4 Nm (36 lb-in).