System Deactivation Procedures
Deactivation Procedure1. Disconnect positive battery cable.
2. Wait one minute. This is the time required for backup power supply in diagnostic monitor to deplete its stored energy.
3. Remove four nut and washer assemblies retaining driver air bag module to steering wheel. Disconnect driver air bag connector. Connect Rotunda Air Bag Simulator 105-00008 or equivalent to vehicle harness at top of steering column.
4. If vehicle is equipped with passenger air bag, remove passenger air bag. The connector will contain the 614 (GY/O) and 616 (PK/BK) circuits. Install air bag simulator on vehicle harness connector.
5. Connect positive battery cable.