Deactivation Procedure
1. Disconnect the negative battery cable.2. Wait one minute. This is the time required for the diagnostic monitor back up power supply to deplete its stored energy.
3. Remove the four bolts retaining the driver air bag module assembly to the steering wheel. Disconnect the driver air bag connector. Connect Rotunda Air Bag Simulator 105-00008 to the vehicle harness at the top of the steering column.
4. Connect the negative battery cable.
5. Perform the necessary tests.