Standby Power Supply: Service and Repair
Backup Power SupplyRemoval
WARNING: THE ELECTRICAL CIRCUIT NECESSARY FOR SYSTEM DEPLOYMENT IS POWERED DIRECTLY FROM THE BATTERY. TO AVOID ACCIDENTAL DEPLOYMENT AND POSSIBLE PERSONAL INJURY, THE BATTERY GROUND CABLE AND THE BATTERY BACKUP MUST BE DISCONNECTED PRIOR TO SERVICING ANY SYSTEM COMPONENTS.
1. Disconnect battery ground cable.
2. Lower the glove compartment door fully by depressing the stops.
3. Detach the battery backup which is a blue rectangular box on the outer LH side of the glove compartment and attached to the instrument panel.
4. Disconnect electrical connector.
5. Remove the backup power supply assembly by depressing the tabs and pulling the assembly up and away from the instrument panel.
Installation
1. Connect the electrical connector.
2. Attach the battery backup to the instrument panel.
3. Install and close the glove compartment.
4. Connect battery ground cable.
5. Verify air bag indicator.