Variable Induction Control Actuator: Service and Repair
REMOVAL1. Remove the plunger retaining clip.
2. Disconnect the actuator vacuum hose.
High Speed Inlet Air (HSIA) Actuator:
3. Remove the actuator mounting bolts and remove the actuator.
High Speed Inlet Air (HSIA) Actuator:
INSTALLATION
1. Place the shutter valve actuator into its mounting position and install the mounting bolts.
2. Connect the actuator vacuum hose.
3. Install the plunger retaining clip.