Compressor
1. Discharge refrigerant from system.
2. Raise and support vehicle.
3. Remove undercover and splash shield.
4. Disconnect drive belt and remove compressor manifold attaching bolts.
5. Cap all compressor and manifold openings to prevent moisture from entering system.
6. Disconnect field coil electrical connector.
7. Remove compressor mounting bolts, then remove compressor.
8. Reverse procedure to install using new O-rings.