Rotor Open or Short Test
Remove the rotor from the alternator. Place the ohmmeter Multiply-By setting at 1 and calibrate the meter.NOTE: Text values shown in brackets [ ]___ are referenced to Rotunda Model 059-00010 and may be different if another tester is used.
1. Contact each ohmmeter probe to a rotor slip ring. The meter reading should be [2.0-3.9]___ohms.
2. A HIGHER reading indicates a damaged slip ring, welded connection or a broken wire. A LOWER reading indicates a shorted wire or slip ring. Replace the rotor.
3. Contact one ohmmeter probe to a slip ring and the other probe to the rotor shaft. The meter reading should be infinite (no needle movement).
4. A reading other than infinite indicates the rotor coil is grounded to the shaft. Replace the rotor if it is grounded and cannot be serviced.