Test 14, Low Pressure Pump Ground Circuit Test
1. Using ohmmeter, check for continuity between a clean underbody ground and ground wire in pump wiring harness.
2. If there is no continuity, repair open in pump ground wire, then repeat TEST 1 to verify pump operation.