AR32.50-P-0022-01RK Initial Start-up of Tandem/Hydraulic Pump
AR32.50-P-0022-01RK Initial Start-Up Of Tandem/Hydraulic Pump
124 589 24 21 00
Pressure pump
166 589 00 91 00
Adapter
Shown on model 220
Air is bled from a new tandem pump when the ABC system is pressurized.
1 Connect suitable pressure hose (084a) to pressure pump (084).
except model 231
2 Pull dipstick out of the expansion reservoir (2).
3 Mount adapter (1) to expansion reservoir (2).
Only on model 231.
3 Insert the pressure hose (084a) into the fitting of the dipstick opening and press on firmly.
2nd person required.
4 Use pressure pump (084) to produce a pressure of approx. 1 bar.
Shown on model 231
5 Mount adapter (1) to expansion reservoir (2).
6 Connect pressure pump (084) to adapter (1)
7 Use pressure pump (084) to produce a pressure of approx. 1 bar.
8 Start engine.