AR40.20-P-0322-03SW Check Caster and Assign to Tabular Value
AR40.20-P-0322-03SW Check caster and assign to tabular value
Check And Adjustment Values For Caster:
Tolerance for caster ± 30'
The level values are displayed by the electronic inclinometer in decimal degrees
RA Rear axle level value
FA Front axle level value
1 Obtain the caster value from the table taking into account the front axle (FA) level values and rear axle (RA) level values measured previously.
Example, see Table:
Front axle level value (FA): +7.0 degrees
Rear axle level value (RA): +1.0 degrees
= Caster value 8 degrees 20' (± 30')