P0665
The actuation for the switchover valve of the intake manifold (cylinder bank 2) has a short circuit to positive.
Check component 'Y77/2 (Intake manifold resonance flap switchover valve)'.
Check component 'Y77/2 (Intake manifold resonance flap switchover valve)' by means of actuation.
Legend:
- 12/2 - Vacuum unit for resonance flap, right
- 12/3 - Vacuum unit for resonance flap, left
- Y77/2 (Intake manifold resonance flap switchover valve)
Note:
During the actuation the linkage of component 'Y77/2 (Intake manifold resonance flap switchover valve)' must move visibly.
Test 1: Continue
1.
Test 1.1: Continue
1.1.
The actuation was OK.
End of test
- The check was OK.
End of test
Result: Pass