P033385
Knock sensor 1 (cylinder bank 2) has a short circuit to positive. There is a signal above the permissible limit value.
Test 1: Continue
1.
Check component '{0}'.
Test 1.1: Continue
1.1.
Check component '{0}' by means of actual value.
- The actual values are not OK.
Possible causes and remedies
- Check electrical lines from component 'N3/10 (ME-SFI [ME] control unit)' to control unit '{1}'.
- A30/2 (Right cylinder bank rear knock sensor)
End of test
End of test
Result: Fail