P0097
Intake air temperature sensor 2 (cylinder bank 1) has a short circuit to ground. There is a short circuit to ground.
Check component 'B17/1 (Intake manifold intake air temperature sensor)'.
Test 1: Continue
1.
Test 1.1: Continue
1.1.
Test 1.1.1: Continue
1.1.1.
The actual value is not OK.
Possible cause and remedy
- Check electrical lines from component 'B17/1 (Intake manifold intake air temperature sensor)' to control unit 'N3/10 (ME-SFI [ME] control unit)' and repair or replace if necessary.
End of test
End of test
Result: Fail