B218E48
Actuation of the radiator shutters has a malfunction. There is an error in the control memory.
Check component 'Y84 (Radiator shutters actuator)'.
Test 1: Continue
1.
Check vacuum supply of component 'Y84 (Radiator shutters actuator)'.
- The vacuum supply is not OK.
Possible causes and remedies
- Vacuum lines and vacuum fittings
- Check component 'A7/7 (BAS brake booster)'.
End of test
End of test
Result: Fail