E1897
Timeout of the PremAir temperature signal
Possible cause:
- B11/15 (PremAir sensor)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check component B11/15 (PremAir sensor).
1. Check component B11/15 (PremAir sensor).
Test 1.1: Check power supply of component B11/15 (PremAir sensor).
Test 1.2: Test signal cable to component B11/15 (PremAir sensor).
Test 1.3: NoteThe PremAir sensor must be firmly latched and bonded to the PremAir radiator.
1.1. Check power supply of component B11/15 (PremAir sensor).
Check power supply of component B11/15 (PremAir sensor).
Test prerequisite
- The actual value is not o.k.
Test sequence
- Switch off ignition.
- Detach coupling at component B11/15 (PremAir sensor).
- Measure direct voltage with multimeter between sockets [ B11/15 ] 1 and [ B11/15 ] 3
- Switch on ignition.
Specified values
- Voltage[ 11.0...14.5] V
Question
- Is the measurement value OK?
YES
The measurement value is OK.Possible cause and remedy
- Signal wire
- B11/15 (PremAir sensor)
End of test
NO
The measurement value is not OK.Possible cause and remedy
- N10/1f57 (Fuse 57)
- N10/1kI (Circuit 87 relay, engine)
- Lines to component B11/15 (PremAir sensor)
End of test
1.2. Test signal cable to component B11/15 (PremAir sensor).
Figure legend
- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test signal cable to component B11/15 (PremAir sensor).
Test sequence
- Switch off ignition.
- Detach coupling at component B11/15 (PremAir sensor).
- Connect socket box (126-pin) to component N3/10 (ME-SFI [ME] control unit).
- Measure resistance with multimeter between socket [F.28] 124 of the 126-pole socket box tester and socket [B11/15] 2
Specified value
- Resistor[< 1 ]ohms
Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Line from control unit N3/10 (ME-SFI [ME] control unit) to component B11/15 (PremAir sensor)
End of test
1.3. NoteThe PremAir sensor must be firmly latched and bonded to the PremAir radiator.
1.3. No further information available.