GF27.19-P-5149ACM Starter Lockout Contact, Component Description
GF27.19-P-5149ACM Starter lockout contact, component description
- TRANSMISSION 722.643/649
- refinement package
- as of model year 09
Component Identification:
Location
The starter lockout contact is located in the electric controller unit and is permanently connected to the conductor tracks.
Task
The starter lockout contacts detects the selector lever positions "P, N".
Component Identification:
Function
The starter lockout contact is operated in selector lever positions "P, N". As a result the permanent magnet is released by the reed contact. The dry-reed contact is opened. The ETC control unit (N15/3) receives an electrical signal. The electric circuit to the starter (M1) is closed in selector lever position "P, N".