GF80.50-P-3014FLU Triggering Alarm With Panic Switch, Function
GF80.50-P-3014FLU Triggering Alarm With Panic Switch, Function
- with CODE (551) Anti-theft alarm system (ATA [EDW])
- with CODE (763) Radio remote control with panic switch
Function requirements, general
^ Terminal 15C OFF
Alarm triggered by panic switch, general
With the panic alarm it is possible to trigger the visual and acoustic antitheft alarm (ATA) with the transmitter key (A8/1) (e.g. in an emergency).
Function sequence when panic alarm and ATA alarm are triggered simultaneously:
The panic alarm has priority over the ATA alarm.
If both alarms are actuated the alarm with the higher priority is output and the ATA alarm is suppressed. This alarm is still actuated in the background. If one of the two alarms is terminated or is interrupted, the other is still actuated.
The alarm triggering with the panic switch comprises the following subfunctions:
^ Function sequence for actuating panic alarm
^ Function sequence for panic alarm output
^ Interrupting function sequence for panic alarm
Function sequence for actuating panic alarm
When the panic alarm button the transmitter key is actuated for t ≥ 2 s, it transmits a radio signal via the FM 1, AM, CL and KEYLESS-GO antenna amplifier (A2/18) to the rear SAM Control unit with fuse and relay module (N10/2). The rear SAM control unit relays the signal to the electronic ignition lock control unit (N73) via the interior CAN (CAN B).
Parallel to the radio signal, an infrared signal is transmitted to the driver front door infrared remote control receiver (A26/1) (precise aiming required).
This signal is read in by the left front door control unit (N69/1) and transmitted to the electronic ignition switch control unit with interior CAN.
In both cases the electronic ignition lock control unit checks the access authorization of the transmitter key.
If the access authorization is valid, the electronic ignition switch control unit transmits the command "Activate panic alarm" to the rear SAM control unit via the interior CAN.
It then transmits the requests for visual and acoustic alarm via interior CAN.
Additional function requirements for panic alarm output
^ Panic alarm triggered
Function sequence for panic alarm output
The alarm output takes place via the exterior lights, the interior illumination as well as up to 31.5.10 via the alarm siren (H3/1) and as of 1.6.10 via the left horn (H2) and the right horn (H2/1). The alarm siren is actuated by the rear SAM control unit via the rear SAM-LIN (LIN B4).
The horns are actuated via the front SAM control unit with fuse and relay module (N10/1) and horns relay (N10/1kO). The interior lights are switched on by the front SAM control unit.
The following components of the exterior lights are actuated:
- by the front SAM control unit:
- Left front turn signal lamp (E1e5)
- Right front turn signal lamp (E2e5)
- by the rear SAM control unit:
- Left rear turn signal lamp (E3e1)
- Right rear turn signal lamp (E4e1)
- by the left front door control unit:
- Left outside mirror turn signal lamp (E6/5)
- By the right front door control unit (N69/2):
- Right outside mirror turn signal lamp (E6/6)
The duration of optical and acoustic panic alarms is identical but stored separately in the alarm siren (up to 31.5.10) and in the rear SAM control unit.
Interrupting function sequence for panic alarm
The panic alarm is interrupted when the panic alarm button on the transmitter key is actuated briefly.
The function sequence for interrupting the panic alarm is the same as for actuating the panic alarm.