P179A78
The redundancy system for DIRECT SELECT has a malfunction. The adaptation or adjustment is incorrect.
Possible cause:
- A80 (Intelligent servo module for DIRECT SELECT)
Affected functions:
- Drive position selection
-------------------------------------------------
Test 1: Remedial action in the event of a fault in the internal mechanical systems of component A80 (Intelligent servo module for DIRECT SELECT)
1. Remedial action in the event of a fault in the internal mechanical systems of component A80 (Intelligent servo module for DIRECT SELECT)
POSSIBLE CAUSES
- Selector lever position "P" was engaged due to a fault occurring in component A80 (Intelligent servo module for DIRECT SELECT) or in the vehicle communications.
Question
- Are other fault codes stored in addition to fault code P179A78?
YES
Preconditions
- There are additional current fault codes shown in control unit A80 (Intelligent servo module for DIRECT SELECT).
Possible remedy
- Process displayed fault codes in control module A80 (Intelligent servo module for DIRECT SELECT).
End of test
NO
Preconditions
- No further current fault codes are stored in control unit A80 (Intelligent servo module for DIRECT SELECT).
Possible remedy
- Perform calibration.
Continue with button "F2"
Perform calibration.
Test prerequisite
- Engine OFF
- Vehicle should be stationary.
- Apply and hold the brakes.
Question
- Is control module ISM to be learned?
YES
Warning!Communication with ECU required.
NO
1. No further information available.