EU113B68
Communication with the DIRECT SELECT lever has a malfunction. There is incomplete information.
Possible cause:
- N80 (Steering column module)
Affected functions:
- Drive position selection
-------------------------------------------------
Test 1: Check the CAN communication with control unit N80 (Steering column module).
Test 2: Fault in CAN communication with control unit N80 (Steering column module).
1. Check the CAN communication with control unit N80 (Steering column module).
Warning!Communication with ECU required.
2. Fault in CAN communication with control unit N80 (Steering column module).
Operation number of operation texts and work units or standard texts and flat rates:27-0641WARNING
- This is not a function error of control module A80 (Intelligent servo module for DIRECT SELECT) and does not justify replacement.
Possible cause for the entry of this event code
- Operational fault of component N80 (Steering column module)
Possible measures
- Read out fault memory of control unit N80 (Steering column module).
- Process displayed fault codes in control module N80 (Steering column module).
End of test