Manufacturer Code Charts: 2805
The signals of the range selector sensor are implausible in comparison to the signals from the electronic selector lever module.
Possible cause:
- Y3/8s1 (Selection range sensor (VGS))
Affected functions:
- Automatic transmission Function
-------------------------------------------------
Test 1: Remedial action after a plausibility error between the signals from components Y3/8s1 (Selection range sensor (VGS)) and N15/5 (Electronic selector lever module control unit)
1. Remedial action after a plausibility error between the signals from components Y3/8s1 (Selection range sensor (VGS)) and N15/5 (Electronic selector lever module control unit)
Operation number of operation texts and work units or standard texts and flat rates:27-0641Cause
- The shift rod is not adjusted correctly.
REMEDY
- Adjust the shift rod as per the repair instructions.
WARNING
- This is not a function error in system 'ETC' and does not justify exchanging components.
- If the complaint occurs repeatedly contact your workshop support.
End of test