14F500
The signal from oxygen sensor 1 (cylinder bank 1) is shifted towards 'Rich'.
Possible cause:
- G3/2 (Oxygen sensor upstream of catalytic converter)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check G3/2 (O2 sensor upstream of KAT) component for carbon fouling.
1. Check G3/2 (O2 sensor upstream of KAT) component for carbon fouling.
Check component G3/2 (O2 sensor upstream of KAT).
Possible cause and remedy
- Check G3/2 (O2 sensor upstream of KAT) component for carbon fouling.
Question
- Is component G3/2 (O2 sensor upstream of KAT) carbon-fouled?
YES
Component G3/2 (O2 sensor upstream of KAT) is carbon-fouled.Possible cause and remedy
- Clean component 'G3/2 (O2 sensor upstream of KAT)'.
End of test
NO
Check component G3/2 (O2 sensor upstream of KAT).
Possible cause and remedy
- Check whether the correct oxygen sensor is installed.
Question
- Is the correct oxygen sensor installed?
YES
Check line from control module N3/9 (CDI control unit) to component G3/2 (O2 sensor upstream of KAT).
Possible cause and remedy
- Check electrical lines and connectors between control unit N3/9 (CDI control unit) and component G3/2 (O2 sensor upstream of KAT) for loose contact and corrosion.
- Check electrical lines and connectors between control unit N3/9 (CDI control unit) and component G3/2 (O2 sensor upstream of KAT) for short and open circuit.
Question
- Are the electrical lines or connectors OK?
YES
The electrical lines or connectors are OK.Possible cause and remedy
- Replace component G3/2 (O2 sensor upstream of KAT).
- After replacing component G3/2 (O2 sensor upstream of KAT), the teach-in process for this component must be performed via menu 'Control unit adaptations'.
- Erase fault memory.
End of test
NO
The electrical lines or connectors are not OK.Possible cause and remedy
- Repair or, if necessary, replace damaged electrical lines and connectors between control unit N3/9 (CDI control unit) and component G3/2 (O2 sensor upstream of KAT).
End of test
NO
An incorrect oxygen sensor is installed.Possible cause and remedy
- Replace component G3/2 (O2 sensor upstream of KAT).
- After replacing component G3/2 (O2 sensor upstream of KAT), the teach-in process for this component must be performed via menu 'Control unit adaptations'.
- Erase fault memory.
End of test