14F100
The signal from oxygen sensor 1 (cylinder bank 1) is shifted towards 'Lean'.
Possible cause:
- G3/2 (Oxygen sensor upstream of catalytic converter)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check component G3/2 (O2 sensor upstream of KAT).
1. Check component G3/2 (O2 sensor upstream of KAT).
Check component G3/2 (O2 sensor upstream of KAT).
Possible cause and remedy
- Check whether the correct oxygen sensor is installed.
Question
- Is the correct oxygen sensor installed?
YES
The correct oxygen sensor is installed.Possible cause and remedy
- Replace component G3/2 (O2 sensor upstream of KAT).
- After replacing component G3/2 (O2 sensor upstream of KAT), the teach-in process for this component must be performed via menu 'Control unit adaptations'.
- Erase fault memory.
End of test
NO
An incorrect oxygen sensor is installed.Possible cause and remedy
- Replace component G3/2 (O2 sensor upstream of KAT).
- After replacing component G3/2 (O2 sensor upstream of KAT), the teach-in process for this component must be performed via menu 'Control unit adaptations'.
- Erase fault memory.
End of test