14E900
The heater for oxygen sensor 1 (cylinder bank 1) has an electrical fault.
Possible cause:
- G3/2 (Oxygen sensor upstream of catalytic converter)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check component G3/2 (O2 sensor upstream of KAT).
1. Check component G3/2 (O2 sensor upstream of KAT).
Possible cause and remedy
- Replace component G3/2 (O2 sensor upstream of KAT).
- After replacing component G3/2 (O2 sensor upstream of KAT), the teach-in process for this component must be performed via menu 'Control unit adaptations'.
- Erase fault memory.
End of test