13C900
There is an internal fault in component N14/3 (Glow output stage).
Possible cause:
- N14/3 (Glow output stage)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Replace component N14/3 (Glow time output stage).
1. Replace component N14/3 (Glow time output stage).
Possible cause and remedy
- Check all lines from component N14/3 (Glow time output stage) to the glow plugs for short circuit to positive.
- Component N14/3 (Glow time output stage) is defective.
This fault caused irreparable damage to at least one glow plug.Procedure
- Switch off ignition.
- Replace component N14/3 (Glow time output stage).
- Coolant temperature<40° C(A lower coolant temperature is required for fault detection.)
- Switch on ignition.
- Read fault memory once again.
- Replace glow plugs found to be defective.
Important note
- For warranty and goodwill claims, you must include a printout of the fault freeze frame data with the component to be replaced.
End of test