120B00
Component Y77/1 (Charge pressure positioner) has Open circuit.
Possible cause:
- Y77/1 (Charge pressure positioner)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check component Y77/1 (Charge pressure positioner).
1. Check component Y77/1 (Charge pressure positioner).
Possible cause and remedy in the case of current fault code
- Test voltage supply (circuit 87) of component Y77/1 (Charge pressure positioner).
- Check ground connection of component Y77/1 (Charge pressure positioner) as per circuit diagram.
- Check line from control unit N3/9 (CDI control unit) (pin M.94) to component Y77/1 (Charge pressure positioner) (pin 4) for open circuit.
Possible cause and remedy in the case of stored fault code
- Inspect wiring and connectors at connection points for loose contacts, corrosion, damage and short circuits. Repair or replace as required.
End of test