[8] Test signal at terminal Terminal 15.: Plausibility error in signal over CAN or hardware line
[8] Test signal at terminal Terminal 15.: Plausibility error in signal over CAN or hardware line
Test 1: CAN bus communication
1. CAN bus communication
Possible cause
- Functional CAN fault
Remedy
- Read fault memory of control unit N73 (EIS [EZS] control unit) and rectify faults.
- Check function impairments using actual values or actuations and restore functionality.
- If present, check codings and correct if necessary.
Note
- A functional CAN fault code is set because of an implausible CAN input signal.
End of test